Standards |
‧IEEE 802.3 10Base-T Ethernet
IEEE 802.3u 100Base-TX Fast Ethernet
‧IEEE 802.3u 100Base-FX Fast Ethernet
IEEE802.3x Flow Control and Back Pressure
‧IEEE802.3af for POE
IEEE802.3at for POE+ |
Switch Architecture |
‧Back-plane (Switching Fabric): 600Mbps |
Data Processing |
‧Store and Forward |
Flow Control |
‧IEEE 802.3x Flow Control and Back Pressure |
MAC Table Size |
‧1K |
Interface |
‧2 x RJ-45 Prot:
10/100M Base-T(X) Auto negotiation, Auto MDI/MDI-X function,
Full/Half duplex, POE+ 802.3af/at 30W PSE port
‧1 x Fiber port:
100 Base-FX SC MM Distance 2km
100 Base-FX SC SM Distance 30km
100 Base-FX ST Distance 2km
100 Base-FX SC MM WDM 1310nm Distance 15km
100 Base-FX SC MM WDM 1550nm Distance 15km |
LED indicators |
‧PW (Power):
Green=power connected
Yellow = alarm being triggered, OFF=normal state
‧TX LEDs:
Green=Link, Flash = TX/RX,
Yellow=POE detected, Flash=power overload
‧Optical Fiber –
Green=Link, Flash =TX/RX |
DIP Switch |
‧Dip 1 – activate port 1 with smart link to alarm relay
‧Dip 2 – activate port 2 with smart link to alarm relay
‧Dip 3 – activate port 3 with smart link to alarm relay
‧Dip 4 – Link Fault Pass-Through ( LFP) Enable |
Power protection |
‧Surge protection diodes on power input
‧Reverse polarity protection
‧Overload current protection |
Power Input Power Consumption |
‧Max power consumption 3 Watts without POE
‧Max POE 30Watts at 56VDC input |
Power Input |
‧VDC 44~56V |
Removable Terminal Block |
‧Provide 4 pin terminal block, V+, V-, and Relay
‧Wire range: 0.34mm^2 to 2.5mm^2
‧Solid wire (AWG):12-24/14-22
‧Stranded wire(AWG): 12-24/14-22
‧Torque:5lb-In/0.5Nm/0.56Nm
‧Wire Strip length: 7-8mm |
Alarm Relay |
‧24VDC @ 1A
‧Normal state – open, Relay LED OFF
‧Triggered states – short, Relay LED ON |
Environment |
‧Operating Temperature: -40°C~75°C
‧Operating Humidity: 5% to 95% (Non-condensing)
‧Storage Temperature: -40°C ~85°C |
Housing |
‧Rugged Metal ,IP30 Protection |
Dimension |
‧103.5mmx32mmx81.5mm (LxWxD) |
Installation mounting |
‧DIN Rail mounted, Wall Mounted |
Safety |
‧IEC EN60950-1 |
EMC/EMS |
‧CE, FCC |
EMI |
‧FCC Part 15 Subpart B Class A, CE EN 55022 Class A |
Vibration |
‧EN 50155 / EN 60068-2-6 |
Shock |
‧EN 50155 / EN 60068-2-27 |
Free Fall |
‧EN 50155 / EN 60068-2-32 |